DCVOLTAGE | 5V | |
LED OPERATION VOLTAGE | 3~5V | |
RATEDCURRENT | 5A | |
CURRENTRANGE | 0~5A | |
RATEDPOWER | 25W | |
RIPPLE&NOISENOTE.2 | 80MVP-P | |
VOLTAGE ADJ RANGE | 4.5~5.5V | |
Can be adjusted by intemal potential meter SVR2 | ||
VOLTAGETOLERANCENOTE.3 | ±5.0% | |
LINEREGULATION | ±1.0% | |
LOADREGULATION | ±2.0% | |
SETUP.RISEHOLD.TIME | 500ms, 80ms/230VAC 1000ms / 115VAC at full load | |
HOLD UP TIME(TYP) | 50ms /230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGERANGE | 90~264VAC |
FREQUENCYRANGE | 47~63HZ | |
EFFICIENCY | 75% | |
AC CURRENT | 0.75A/115VAC 0.48A/230VAC | |
INRUSH CURRENT | Cold start 60A/230vac | |
LEAKAGECURRENT | 0.25mA/240VAC | |
PROTECTION | OVER CURRENT | 95~110% |
Protection typeConstant current limiting,recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 5.75~6.75V | |
Protection typeShut down o/p voltage,re-power on to recover. | ||
FUNCTION | DIMMING CONTROL (OPTIONAL) | 1~10VDC or PWM |
ENVIRONMENT | WORKINGTIMP | -20~+60(refer to output load derating curve) |
WORKINGHUMIDITY | -20~90%Rhnon-condensing | |
STORAGE TEMP HUMIDITY | -40~+80 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%(0~50) | |
VIBRATION | 10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes | |
SAFETY&EMC | SAFETYSTANDARDS | Design refer to UL1310 Class 2,TUV EN60950-1,EN61347-2-13,CAN/CSA C22.2 NO.223-M91M,IP67 approved |
WITHSTAND VOLTAGE | 1/P-0/P:3KVAC | |
ISOLATIONRESISTANCE | 1/P-0/P:>100M Ohms/500VDC/25/70%RH | |
EMI CONDUCTICN& RADIATION | Compliance to EN55022(CISPR22)classB | |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA | |
QTHERS | MTBF | 628.3Khrs min MIL-HDBK-217F(25) |
DIMENSION | 145*47*30mm(L*W*H) | |
PACKING | 0.26Kg 60pcs / 16.6Kg / 1.25CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Derating may be needed under low input voltage.please check the derating curve for more details. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meet EMC directives. 6.Length of set up time is measured at first.tuming ON/OFF the power supply may lead to increase of the set up time . 7.Constant current operation region is within the specified output voltage above. This is suitable operation region for LED related applications |